Simulation of the human airways using virtual topology tools and meshing optimization

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Marcos, A. C.
  • Agujetas, R.
  • Ferrera, C.

Abstract

A method is proposed to improve the quality of the three-dimensional airway geometric models using a commercial software, checking the number of elements, meshing time, and aspect ratio and skewness parameters. The use of real and virtual topologies combined with patch-conforming and patch-independent meshing algorithms results in four different models being the best solution the combination of virtual topology and patch-independent algorithm, due to an excellent aspect ratio and skewness of the elements, and minimum meshing time. The result is a reduction in the computational time required for both meshing and simulation due to a smaller number of cells. The use of virtual topologies combined with patch-independent meshing algorithms could be extended in bioengineering because the geometries handling is similar to this case. The method is applied to a healthy person using their computed tomography images. The resulting numerical models are able to simulate correctly a forced spirometry.

Datos de la publicación

ISSN/ISSNe:
1617-7959, 1617-7940

Biomechanics and Modeling in Mechanobiology  SPRINGER HEIDELBERG

Tipo:
Article
Páginas:
465-477
PubMed:
29105007

Citas Recibidas en Web of Science: 3

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Keywords

  • Human airways; CT images; CFD; Virtual topology; Meshing optimization

Cita

Compartir