Adjustment of Intrastromal Corneal Ring Segments After Unsuccessful Implantation in Keratoconic Eyes
Autores con afiliación ISPA
Otros autores
- Monteiro, T
- Mendes, JF
- Faria-Correia, F
- Franqueira, N
- Madrid-Costa, D
Grupos y Plataformas
Abstract
Purpose: To evaluate visual, refractive, and corneal topography outcomes in eyes with keratoconus that have undergone exchange/adjustment surgery with a new intrastromal corneal ring segment (ICRS) combination after unsuccessful visual and/or refractive outcomes after primary ICRS surgery. Methods: A retrospective nonrandomized case series was conducted including consecutive eyes of patients with keratoconus that underwent ICRS adjustment after an unsuccessful visual outcome. Patients were divided into 2 groups: group 1 was made up of patients with Intacs ICRSs that were exchanged for the Ferrara ICRS type, and group 2 consisted of patients who maintained the same ICRS type after undergoing ICRS adjustment surgery (change of the arc length or thickness). Uncorrected distance visual acuity, best-corrected distance visual acuity (CDVA), keratometry, asphericity, higher-order aberrations, and corneal regularity indexes (ISV and IHD) (Pentacam HR; OCULUS) were assessed preoperatively and 12 months after each procedure. Results: Twenty-six eyes from 26 patients were included, 8 eyes in group 1 and 18 eyes in group 2. The eyes in both groups improved their CDVA values after ICRS exchange, in group 1 from 0.27 +/- 0.11 preoperatively to 0.54 +/- 0.17 postoperatively (P = 0.001), and in group 2 from 0.34 +/- 0.22 to 0.61 +/- 0.15 (P < 0.0001). In both groups, there was also a significant improvement in the refractive cylinder, topographic cylinder, and coma after ICRS adjustment (P < 0.05). Conclusions: ICRS implantation has been shown to be a reversible and adjustable surgical procedure for keratoconus treatment. Good outcomes can be obtained after ICRSs are exchanged.
Datos de la publicación
- ISSN/ISSNe:
- 0277-3740, 1536-4798
- Tipo:
- Article
- Páginas:
- 182-188
- PubMed:
- 29135710
CORNEA LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 11
Documentos
- No hay documentos
Filiaciones
Keywords
- keratoconus; intrastromal corneal ring segments; adjustment
Cita
Monteiro, T; Mendes, JF; Faria Correia, F; Franqueira, N; Madrid Costa, D; Alfonso, JF. Adjustment of Intrastromal Corneal Ring Segments After Unsuccessful Implantation in Keratoconic Eyes. Cornea. 2018. 37. (2). p. 182-188. DOI: 10.1097/ICO.0000000000001449.
Portal de Investigación