Diagnostic accuracy of the Xpert (R) MTB/RIF cycle threshold level to predict smear positivity: a meta-analysis

Fecha de publicación:

Autores con afiliación ISPA

  • Juan José Palacios Gutiérrez

    Autor

Otros autores

  • Lange, B
  • Khan, P
  • Kalmambetova, G
  • Al-Darraji, HA
  • Alland, D
  • Antonenka, U
  • Brown, T
  • Balcells, ME
  • Blakemore, R
  • Denkinger, CM
  • Dheda, K
  • Hoffmann, H
  • Kadyrov, A
  • Lemaitre, N
  • Miller, MB
  • Nikolayevskyy, V
  • Ntinginya, EN
  • Ozkutuk, N
  • Popowitch, EB
  • Porcel, JM
  • Teo, J
  • Theron, G
  • Kranzer, K

Abstract

SETTING: Xpert (R) MTB/RIF is the most widely used molecular assay for rapid diagnosis of tuberculosis (TB). The number of polymerase chain reaction cycles after which detectable product is generated (cycle threshold value, C-T) correlates with the bacillary burden. OBJECTIVE: To investigate the association between Xpert C-T values and smear status through a systematic review and individual-level data meta-analysis. DESIGN: Studies on the association between C-T values and smear status were included in a descriptive systematic review. Authors of studies including smear, culture and Xpert results were asked for individual-level data, and receiver operating characteristic curves were calculated. RESULTS: Of 918 citations, 10 were included in the descriptive systematic review. Fifteen data sets from studies potentially relevant for individual-level data meta-analysis provided individual-level data (7511 samples from 4447 patients); 1212 patients had positive Xpert results for at least one respiratory sample (1859 samples overall). ROC analysis revealed an area under the curve (AUC) of 0.85 (95%CI 0.82-0.87). Cut-off C-T values of 27.7 and 31.8 yielded sensitivities of 85% (95%CI 83-87) and 95% (95%C1 94-96) and specificities of 67% (95%CI 66-77) and 35% (95%CI 30-41) for smear-positive samples. CONCLUSION: Xpert CT values and smear status were strongly associated. However, diagnostic accuracy at set cut-off C-T values of 27.7 or 31.8 would not replace smear microscopy. How C-T values compare with smear microscopy in predicting infectiousness remains to be seen.

Datos de la publicación

ISSN/ISSNe:
1027-3719, 1815-7920

INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE  INT UNION AGAINST TUBERCULOSIS and LUNG DISEASE (I U A T L D)

Tipo:
Article
Páginas:
493-502
PubMed:
28399963

Citas Recibidas en Web of Science: 13

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • systematic review; diagnosis; Xpert; cycle threshold value

Cita

Compartir