Diagnostic accuracy of the Xpert (R) MTB/RIF cycle threshold level to predict smear positivity: a meta-analysis
Autores con afiliación ISPA
Otros autores
- Lange, B
- Khan, P
- Kalmambetova, G
- Al-Darraji, HA
- Alland, D
- Antonenka, U
- Brown, T
- Balcells, ME
- Blakemore, R
- Denkinger, CM
- Dheda, K
- Hoffmann, H
- Kadyrov, A
- Lemaitre, N
- Miller, MB
- Nikolayevskyy, V
- Ntinginya, EN
- Ozkutuk, N
- Popowitch, EB
- Porcel, JM
- Teo, J
- Theron, G
- Kranzer, K
Abstract
SETTING: Xpert (R) MTB/RIF is the most widely used molecular assay for rapid diagnosis of tuberculosis (TB). The number of polymerase chain reaction cycles after which detectable product is generated (cycle threshold value, C-T) correlates with the bacillary burden. OBJECTIVE: To investigate the association between Xpert C-T values and smear status through a systematic review and individual-level data meta-analysis. DESIGN: Studies on the association between C-T values and smear status were included in a descriptive systematic review. Authors of studies including smear, culture and Xpert results were asked for individual-level data, and receiver operating characteristic curves were calculated. RESULTS: Of 918 citations, 10 were included in the descriptive systematic review. Fifteen data sets from studies potentially relevant for individual-level data meta-analysis provided individual-level data (7511 samples from 4447 patients); 1212 patients had positive Xpert results for at least one respiratory sample (1859 samples overall). ROC analysis revealed an area under the curve (AUC) of 0.85 (95%CI 0.82-0.87). Cut-off C-T values of 27.7 and 31.8 yielded sensitivities of 85% (95%CI 83-87) and 95% (95%C1 94-96) and specificities of 67% (95%CI 66-77) and 35% (95%CI 30-41) for smear-positive samples. CONCLUSION: Xpert CT values and smear status were strongly associated. However, diagnostic accuracy at set cut-off C-T values of 27.7 or 31.8 would not replace smear microscopy. How C-T values compare with smear microscopy in predicting infectiousness remains to be seen.
Datos de la publicación
- ISSN/ISSNe:
- 1027-3719, 1815-7920
- Tipo:
- Article
- Páginas:
- 493-502
- PubMed:
- 28399963
INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE INT UNION AGAINST TUBERCULOSIS and LUNG DISEASE (I U A T L D)
Citas Recibidas en Web of Science: 13
Documentos
- No hay documentos
Filiaciones
Keywords
- systematic review; diagnosis; Xpert; cycle threshold value
Cita
Lange, B; Khan, P; Kalmambetova, G; Al Darraji, HA; Alland, D; Antonenka, U; Brown, T; Balcells, ME; Blakemore, R; Denkinger, CM; Dheda, K; Hoffmann, H; Kadyrov, A; Lemaitre, N; Miller, MB; Nikolayevskyy, V; Ntinginya, EN; Ozkutuk, N; Palacios, JJ; Popowitch, EB; Porcel, JM; Teo, J; Theron, G; Kranzer, K. Diagnostic accuracy of the Xpert (R) MTB/RIF cycle threshold level to predict smear positivity: a meta-analysis. Int. J. Tuberc. Lung Dis. 2017. 21. (5). p. 493-502. DOI: 10.5588/ijtld.16.0702.
Portal de Investigación