Comparison of MB-Check and Lowenstein-Jensen media for recovery of mycobacteria

Fecha de publicación:

Autores con afiliación ISPA

  • Juan José Palacios Gutiérrez

    Autor

Otros autores

  • Garcia, JM
  • Ferro, J
  • Rodriguez, J
  • Sanchez, A
  • Villar, H
  • Muniz, MM
  • Marron, MG
  • Ozores, M
  • Calvo, C
  • Prendes, P

Abstract

We have compared the rate of recovery of mycobacteria with the MB-Check culture system (liquid phase) and the Lowenstein-Jensen (LJ) medium in 2,907 clinical specimens obtained from 830 patients submitted for mycobacterial culture during 1-year period. Direct smear examination was carried out by auramine-rhodamine staining. All primary isolates from the culture media were confirmed by Ziehl-Neelsen staining and identified by acridinium-ester-labeled DNA probes specific for Mycobaterium tuberculosis complex. A total of 214 isolates were of the M. tuberculosis complex (88 patients) and 54 of ''potentially pathogenic environmental mycobacteria'' (45 patients). A total of 117 (54.7%) samples were smear-positive and the remaining 97 (45.3%) were smear-negative. There was a significant difference in the percentage of positive cultures obtained by the MB-Check method (99.1%) as compared with the LJ medium (73.8%) (P < 0.05). This difference, however, occurred almost exclusively at the expense of the 97 smear-negative samples (positive cultures 97.95% by the MB-Check method us. 42.3% by the LJ culture, P < 0.05). The number of patients diagnosed of tuberculosis by the MB-Check was significantly higher as compared with LJ medium (88 [100%] vs. 77 [87.5%], P < 0.05). In 11 (12.5%) patients, the diagnosis was only established by the MB-Check system. In smear-positive samples, the mean (+/-SD) detection time for M. tuberculosis complex was 14.8 +/- 8 days with MB-Check and 19.9 +/- 7 days with LJ medium. The corresponding figures in smear-negative samples were 22.8 +/- 3 days and 27.8 +/- 6 days, respectively. DNA probes directly applied to MB-Check liquid medium showed a sensitivity of 98.8% and specificity of 100%. These results indicate that the MB-Check system is more efficient for the recovery of mycobacteria than LJ medium. (C) 1997 Wiley-Liss, Inc.

Datos de la publicación

ISSN/ISSNe:
1059-910X, 1097-0029

MICROSCOPY RESEARCH AND TECHNIQUE  WILEY

Tipo:
Article
Páginas:
512-518
PubMed:
9376655

Citas Recibidas en Web of Science: 4

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Keywords

  • tuberculosis; diagnosis; Mycobacterium tuberculosis; Septi-Chek AFB; culture media; DNA probes

Cita

Compartir