Clear lens extraction for the correction of high myopia

Fecha de publicación:

Autores con afiliación ISPA

Abstract

Objective: To evaluate the postoperative outcomes and intraoperative and postoperative complications of clear lens extraction (CLE) with posterior chamber intraocular lens (IOL) implantation in highly myopic eyes. Design: Retrospective case series. Participants: One hundred seven patients (190 eyes) who had undergone CLE with posterior chamber IOL implantation and who had been observed for at least 3 years after surgery. Methods: Medical records of patients who had undergone CLE with posterior chamber IOL implantation to treat high myopia (axial length >26.00 mm) over 7 years (January 1990 to December 1996) were reviewed. Visual acuity and refractive error were assessed before and after surgery, and perioperative, intraoperative, and postoperative complications were recorded. Main Outcome Measures: Axial length, preoperative and final best spectacle-corrected visual acuity (BSCVA), preoperative and postoperative spherical equivalent (SE), argon laser treatments, surgical complications, neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy, retinal detachment (RD), time from surgery or Nd:YAG capsulotomy to RD, subfoveal choroidal neovascularization (CNV), and,follow-up period. Results: The mean postoperative follow-up period was 4.78 years (range, 3.10-8.03 years). Final BSCVA was better than preoperative BSCVA in 159 eyes (83.68%), equal in 24 eyes (12.63%), and worse in 7 eyes (3.68%). Postoperative BSCVA was 20/40 or better in 136 eyes (71.60%) vs. 52 eyes (27.36%) before surgery (P<0.001). The mean final postoperative SE was -1.22 diopters. The risk of Nd:YAG laser capsulotomy was 77.89%. The incidence of RD was 2.10%; retinal reattachment was achieved in all cases, and none of these eyes had worse final BSCVA than before Surgery. Subfoveal CNV developed in 4 eyes (2.10%) of 3 patients; all of these eyes presented with a macular lacquer crack. Conclusions: Clear lens extraction with posterior chamber IOL implantation has good outcomes with acceptable predictability and improvement in best-corrected visual acuity. During follow-up, patients tended to remain stable, and the risk of retinal detachment was low. We attribute our favorable results to careful patient selection and follow-up. (C) 2003 by the American Academy of Ophthalmology.

Datos de la publicación

ISSN/ISSNe:
0161-6420, 1549-4713

OPHTHALMOLOGY  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
2349-2354
PubMed:
14644717

Citas Recibidas en Web of Science: 63

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Cita

Compartir