A UHPLC method for the simultaneous analysis of biogenic amines, amino acids and ammonium ions in beer

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Redruello, B
  • Martin, MC

Abstract

This paper reports a novel UHPLC method for simultaneously quantifying nine biogenic amines, 21 amino acids, and ammonium ions, in beer. Precision values of standard curves slopes were lower than 3.4% and recovery was between 85% and 106%, indicating the absence of matrix effect. Linear calibration curves were obtained for analyte concentrations between two and four orders of magnitude (R-2 > 0.996). Repeatability tests returned mean variations of 3.2% and 0.5% for beer and a standard solution, respectively. Sensitivity ranged between 0.03 mg/L and 0.63 mg/L for the biogenic amines, and 0.05 mg/L and 5.19 mg/L for other compounds. Original data on the habitual presence of ethanolamine in beers are presented. The method allows for more samples to be assayed per unit time, it uses less solvent than other techniques and therefore reduces costs and the associated waste. It could be a valuable tool for monitoring the safety and quality of beers. (C) 2016 Elsevier Ltd. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0308-8146, 1873-7072

Food Chemistry  ELSEVIER SCI LTD

Tipo:
Article
Páginas:
117-124
PubMed:
27664616

Citas Recibidas en Web of Science: 60

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Biogenic amines; Amino acid; UHPLC; DEEMM; Beer

Cita