Maximal Oxygen Uptake Cannot Be Estimated From Resting Lung Function and Submaximal Exercise in Patients With Chronic Obstructive Pulmonary Disease

Fecha de publicación:

Autores con afiliación ISPA

  • Pere Casan Clarà

    Autor

Otros autores

  • Fregonezi, G
  • Resqueti, V
  • Vigil, L
  • Calaf, N

Abstract

BACKGROUND: Maximal oxygen uptake (<(V)over dot>(O2max)) obtained from incremental exercise testing is a useful indicator of limited exercise capacity. Several prediction equations have been developed to estimate <(V)over dot>(O2max) in patients with chronic obstructive pulmonary disease (COPD), but agreement studies between estimated and measured <(V)over dot>(O2max) are lacking. This study aims to assess agreement between the 6 estimated <(V)over dot>(O2max) equations and direct measures of <(V)over dot>(O2max) evaluated during maximal incremental exercise testing in male COPD patients. METHODS: Patients with stable COPD, in accordance with GOLD guidelines, were included in the study. Agreement between <(V)over dot>(O2max) obtained during incremental exercise testing and <(V)over dot>(O2max) obtained from 6 prediction equations were studied. To estimate <(V)over dot>(O2max) from anthropometric prediction equations, lung function variables and submaximal exercise testing were used. RESULTS: Of the 60 male patients in the study, 12 were GOLD stage II, 24 GOLD stage III, and 24 GOLD stage IV. Five prediction equations underestimated the value of <(V)over dot>(O2max) in relation to measured <(V)over dot>(O2max): equations 1, 2, 3, 4, and 6, by 14%, 66%, 42.2%, 35%, and 23.3%, respectively. Conversely, prediction equation 5 overestimated measured <(V)over dot>(O2max) by 76.9%. Agreement between all <(V)over dot>(O2max) prediction equations and measured <(V)over dot>(O2max) was poor. Discrepancy between <(V)over dot>(O2max) prediction equations and measured <(V)over dot>(O2max) varied from -0.857 to 0.736 L/min. CONCLUSIONS: The use of lung function at rest and submaximal exercise testing is inaccurate for determining <(V)over dot>(O2max), which cannot be estimated by prediction equations in patients with stable COPD.

Datos de la publicación

ISSN/ISSNe:
1932-7501, 1932-751X

Journal of Cardiopulmonary Rehabilitation and Prevention  LIPPINCOTT WILLIAMS & WILKINS

Tipo:
Article
Páginas:
219-225
PubMed:
22691941

Citas Recibidas en Web of Science: 4

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • chronic obstructive pulmonary disease; exercise tests; pulmonary function tests

Compartir