Measuring Breathing Pattern in Patients With Chronic Obstructive Pulmonary Disease by Electrical Impedance Tomography

Fecha de publicación:

Autores con afiliación ISPA

  • Pere Casan Clarà

    Autor

Otros autores

  • Balleza, M
  • Calaf, N
  • Feixas, T
  • Gonzalez, M
  • Anton, D
  • Riu, PJ

Abstract

Background and Objective: The measurement of breathing pattern in patients with chronic obstructive pulmonary disease (COPD) by electrical impedance tomography (EIT) requires the use of a mathematical calibration model incorporating not only anthropometric characteristics (previously evaluated in healthy individuals) but probably functional alterations associated with COPD as well. The aim of this study was to analyze the association between Err measurements and spirometry parameters, static lung volumes, and carbon monoxide diffusing capacity (DLCO) in a group of male patients to develop a calibration equation for converting Err signals into volume signals. Materials and Methods: We measured forced vital capacity (FVC), forced expiratory volume in I second (FEV1), FEV1/FVC, residual volume, total lung capacity, DLCO, carbon monoxide transfer coefficient (KCO) and standard anthropometric parameters in 28 patients with a FEV1/FVC ratio of < 70%. We then compared tidal volume measurements from a previously validated EIT unit and a standard pneumotachometer. Results: The mean (SD) lung function results were FVC, 72 (16%); FEV1, 43% (14%); FEV1/FVC, 42% (9%); residual volume, 161% (44%); total lung capacity, 112% (17%): DLCO, 58% (17%); and KCO, 75% (25%). Mean (SD) tidal volumes measured by the pneumotachometer and the EIT unit were 0.697 (0.181)L and 0.515 (0.223) L, respectively (P <.001). Significant associations were found between EIT measurements and CO transfer parameters. The mathematical model developed to adjust for the differences between the 2 measurements (R-2 = 0.568; P<.001) was compensation factor = 1.81#-0.82# x height (m)#-0.004 x KCO (%) Conclusions: The measurement of breathing pattern by EIT in patients with COPD requires the use of a previously calculated calibration equation that incorporates not only individual anthropometric characteristics but gas exchange parameters as well. (C) 2008 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0300-2896, 1579-2129

ARCHIVOS DE BRONCONEUMOLOGIA  ELSEVIER ESPANA SLU

Tipo:
Article
Páginas:
320-324
PubMed:
19497652

Citas Recibidas en Web of Science: 18

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Electrical impedance iomography (EIT); Breathing pattern; Pneumotacometer; Calibration