Randomised evaluation of a novel biodegradable polymer-based sirolimus-eluting stent in ST-segment elevation myocardial infarction: the MASTER study
Autores con afiliación ISPA
Otros autores
- Valdes-Chavarri, M
- Kedev, S
- Neskovic, AN
- Zivkovic, M
- Nouche, RT
- Gonzalez, NV
- Bartorelli, AL
- Antoniucci, D
- Tamburino, C
- Colombo, A
- Abizaid, A
- McFadden, E
- Garcia-Garcia, HM
- Milasinovic, D
- Stankovic, G
Grupos y Plataformas
Abstract
Aims: The MASTER study was designed to compare the performance of a new biodegradable polymer sirolimus-eluting stent (BP-SES) with a bare metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI). Methods and results: The study was a prospective, randomised (3:1), controlled, single-blind multicentre trial that enrolled 500 STEMI patients within 24 hours of symptom onset during 2013-2015. Three hundred and seventy-five patients were treated with BP-SES and 125 with BMS. One hundred and four (104) randomised patients underwent angiographic follow-up at six months. The primary clinical endpoint was target vessel failure (TVF), defined as cardiac death, MI not clearly attributable to a non-target vessel, or clinically driven target vessel revascularisation (TVR) at 12 months. The primary angiographic endpoint was in-stent late lumen loss (LLL) at six months in the angiographic cohort. The major secondary endpoint for safety was a composite of all-cause death, recurrent MI, unplanned infarct-related artery revascularisation, stroke, definite stent thrombosis (ST) or major bleeding at one month. At 12 months, TVF had occurred in 6.1% of BP-SES and 14.4% of BMS patients (p(non-inferiority)=0.0004), mainly driven by a higher rate of repeat revascularisation in BMS patients. The safety endpoint occurred in 3.5% of BP-SES and 7.2% of BMS patients (p=0.127). In-stent LLL demonstrated the superiority (p=0.0125) of BP-SES (0.09 +/- 0.43 mm) over BMS (0.79 +/- 0.67 mm). Conclusions: The study showed clinical non-inferiority and angiographic superiority of BP-SES versus a comparator BMS, suggesting that this novel DES may be a potential treatment option in STEMI.
Datos de la publicación
- ISSN/ISSNe:
- 1774-024X, 1969-6213
- Tipo:
- Article
- Páginas:
- 1836-1842
- PubMed:
- 29957593
EuroIntervention EUROPA EDITION
Citas Recibidas en Web of Science: 11
Documentos
- No hay documentos
Filiaciones
Keywords
- bare metal stent; drug-eluting stent; STEMI
Cita
Valdes Chavarri, M; Kedev, S; Neskovic, AN; de la Tassa, CM; Zivkovic, M; Nouche, RT; Gonzalez, NV; Bartorelli, AL; Antoniucci, D; Tamburino, C; Colombo, A; Abizaid, A; McFadden, E; Garcia, HM; Milasinovic, D; Stankovic, G. Randomised evaluation of a novel biodegradable polymer-based sirolimus-eluting stent in ST-segment elevation myocardial infarction: the MASTER study. EuroIntervention. 2019. 14. (18). p. 1836-1842. DOI: 10.4244/EIJ-D-17-01087.
Portal de Investigación