Implantable collamer lens with central hole: 3-year follow-up

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Fernandez-Vega-Cueto, L
  • Lisa, C
  • Esteve-Taboada, JJ
  • Montes-Mico, R

Grupos y Plataformas

Abstract

Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia. Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of the V4c ICL. The refraction, uncorrected distance visual acuity, best-corrected distance visual acuity, IOP, endothelial cell count, vault, and adverse effects were evaluated every 12 months during the whole follow-up. Results: The mean spherical equivalent dropped from -8.30 +/- 2.98 D preoperatively to -0.37 +/- 0.47 D at 36 months post-surgery, with 91.8% eyes being within +/- 1.00 D of emmetropia. With respect to the astigmatic components J0 and J45, 98.4% and 99.5% of eyes, respectively, were within +/- 0.50 D of the desired refraction. At 36 months, 78.8% of eyes had no change in the Snellen lines of best-corrected distance visual acuity, while 8.7% gained one line and 6.5% gained two or more lines; mean safety and efficacy indexes were 1.03 and 0.90, respectively. Mean endothelial cell count was 2,742 +/- 340 cells/mm(2) before and 2,663 +/- 366 cells/mm(2) at 36 months post-surgery. Mean IOP reduced from 13.7 +/- 1.9 mmHg preoperatively to 12.8 +/- 1.7 mmHg at 36 months post-surgery. Mean vault varied from 409 +/- 196 mu m at 12 months to 349 +/- 165 mu m at 36 months. Conclusion: The visual and refractive outcomes were very good and highly stable throughout the follow-up period, indicating that this ICL model may be predictable, stable, safe, and effective to correct myopia in the long term.

Datos de la publicación

ISSN/ISSNe:
1177-5483, 1177-5483

Clinical Ophthalmology  DOVE MEDICAL PRESS LTD

Tipo:
Article
Páginas:
2015-2029
PubMed:
30349185

Citas Recibidas en Web of Science: 31

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • phakic intraocular lens; implantable collamer lens; Visian ICL; long-term evaluation

Compartir