Embolic protection devices in saphenous percutaneous intervention
Autores con afiliación ISPA
Otros autores
- Lozano, I.
- Martín, M.
- Rondán, J.
Abstract
Saphenous veins remain a source conduit for use in surgical coronary bypass graft revascularisation procedures. Saphenous vein grafts have a progressive closure rate estimated to be 12% to 20% at the end of the first year, and approximately 50% by 10 years. Regarding secondary revascularisation in these cases, reoperation carries substantially increased morbidity and mortality rates, making saphenous coronary intervention, in particular stent implantation, a more attractive means of revascularisation. However, this procedure carries a significant risk of major adverse clinical events, predominantly myocardial infarction or reduced antegrade flow (non-reflow phenomenon), mainly due to distal embolisation of atherothrombotic debris and distal microvascular occlusion. Embolic protection devices are used to reduce the risk of distal embolisation. There are two different designs: filter and occlusion-aspiration devices. In this article we present the different systems of embolic protection devices in saphenous percutaneous intervention and the previously published information is reviewed. © Europa Edition. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 1774-024X, 1969-6213
- Tipo:
- Review
- Páginas:
- 45-50
- PubMed:
- 19736070
- Enlace a otro recurso:
- www.scopus.com
EuroIntervention EUROPA EDITION
Citas Recibidas en Scopus: 7
Documentos
- No hay documentos
Métricas
Filiaciones
Keywords
- Coronary angioplasty; Coronary bypass grafting; Embolism; Secondary coronary revascularisation; balloon embolization; clinical trial; contrast enhancement; coronary artery bypass graft; device; embolic protection device; equipment design; guide wire; heart death; heart infarction; heart muscle ischemia; human; intermethod comparison; morbidity; mortality; percutaneous coronary intervention; percutaneous transluminal angioplasty; reoperation; revascularization; review; saphenous vein graft; vein embolism; Angioplasty, Transluminal, Percutaneous Coronary; Balloon Occlusion; Coronary Artery Bypass; Coronary Artery Disease; Embolism; Equipment Design; Filtration; Graft Occlusion, Vascular; Humans; Myocardial Infarction; No-Reflow Phenomenon; Saphenous Vein; Stents; Suction; Treatment Failure
Cita
Morís, C; Lozano, I; Martín, M; Rondán, J; Avanzas, P. Embolic protection devices in saphenous percutaneous intervention. EuroIntervention. 2009. 5. p. 45-50.