Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis: The International FORWARD Study
Fecha de publicación:
Autores con afiliación ISPA
Otros autores
- Van Mieghem, N.M.
- Tchétché, D.
- Walton, A.
- Oh, J.K.
- Qiao, H.
- Grube, E.
- Windecker, S.
- Sinhal, A.
- Gooley, R.
- Walton, T.
- Yong, G.
- Bosmans, J.
- Webb, J.
- Chu, M.
- Radhakrishnan, S.
- Dager, A.
- Branny, M.
- Tchetche, D.
- Modine, T.
- Teiger, E.
- Chevalier, B.
- Himbert, D.
- Schymik, G.
- Zeus, T.
- Jensen, C.
- Rassaf, T.
- Fichtlscherer, S.
- Nickenig, G.
- Linke, A.
- Bleiziffer, S.
- Kempfert, J.
- Scholtz, W.
- Harnath, A.
- Strasser, R.
- Frerker, C.
- Spargias, K.
- Merkely, B.P.
- Finkelstein, A.
- Tamburino, C.
- Colombo, A.
- Petronio, A.S.
- Fiorina, C.
- Bedogni, F.
- Amoroso, G.
- van der Heijden, J.
- Van Mieghem, N.
- Tonino, P.
- Echeverria Beliz, P.
- Witkowski, A.
- Gama Ribeiro, V.
- Al Abdullah, M.
- Weich, H.
- Trillo, R.
- Hernández García, J.M.
- Jönsson, A.L.
- Malkin, C.J.
- Khogali, S.
- Hildick-Smith, D.
- Manoharan, G.
Abstract
Background Clinical outcomes in large patient populations from real-world clinical practice with a next-generation self-expanding transcatheter aortic valve are lacking. Objectives This study sought to document the clinical and device performance outcomes of transcatheter aortic valve replacement (TAVR) with a next-generation, self-expanding transcatheter heart valve (THV) system in patients with severe symptomatic aortic stenosis (AS) in routine clinical practice. Methods The FORWARD (CoreValve Evolut R FORWARD) study is a prospective, single-arm, multinational, multicenter, observational study. An independent clinical events committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms. From January 2016 to December 2016, TAVR with the next-generation self-expanding THV was attempted in 1,038 patients with symptomatic, severe AS at 53 centers on 4 continents. Results Mean age was 81.8 ± 6.2 years, 64.9% were women, the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 5.5 ± 4.5%, and 33.9% of patients were deemed frail. The repositioning feature of the THV was applied in 25.8% of patients. A single valve was implanted in the proper anatomic location in 98.9% of patients. The mean aortic valve gradient was 8.5 ± 5.6 mm Hg, and moderate or severe aortic regurgitation was 1.9% at discharge. All-cause mortality was 1.9%, and disabling stroke occurred in 1.8% at 30 days. The expected-to-observed early surgical mortality ratio was 0.35. A pacemaker was implanted in 17.5% of patients. Conclusions TAVR using the next-generation THV is clinically safe and effective for treating older patients with severe AS at increased operative risk. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369) © 2017 American College of Cardiology Foundation
Datos de la publicación
- ISSN/ISSNe:
- 0735-1097, 1558-3597
- Tipo:
- Article
- Páginas:
- 845-853
- PubMed:
- 28797353
- Enlace a otro recurso:
- www.scopus.com
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 84
Citas Recibidas en Scopus: 54
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- aortic stenosis; degenerative valve; transcatheter aortic valve replacement; aged; aortic regurgitation; aortic stenosis; Article; catheter sheath; cerebrovascular accident; clinical effectiveness; clinical outcome; device embolization; device migration; disease severity; echocardiography; female; frailty; heart valve bioprosthesis; human; major clinical study; male; mortality risk; observational study; pacemaker; pacemaker implantation; patient risk; priority journal; prosthetic valve dysfunction; prosthetic valve thrombosis; self expanding transcatheter aortic valve prosthesis; surgical mortality; surgical risk; transcatheter aortic valve implantation; very elderly; aortic valve stenosis; cause of death; clinical trial; follow up; global health; heart valve prosthesis; mortality; multicenter study; multidetector computed tomography; procedures; prospective study; prosthesis design; risk factor; severity of illness index; survival rate; time factor; transcatheter aortic valve implanta
Cita
Van Mieghem, NM; Tchétché, D; Walton, A; Oh, JK; Qiao, H; Grube, E; Windecker, S; Sinhal, A; Gooley, R; Walton, T; Yong, G; Bosmans, J; Webb, J; Chu, M; Radhakrishnan, S; Dager, A; Branny, M; Tchetche, D; Modine, T; Teiger, E; Chevalier, B; Himbert, D; Schymik, G; Zeus, T; Jensen, C; Rassaf, T; Fichtlscherer, S; Nickenig, G; Linke, A; Bleiziffer, S; Kempfert, J; Scholtz, W; Harnath, A; Strasser, R; Frerker, C; Spargias, K; Merkely, BP; Finkelstein, A; Tamburino, C; Colombo, A; Petronio, AS; Fiorina, C; Bedogni, F; Amoroso, G; van der Heijden, J; Van Mieghem, N; Tonino, P; Echeverria Beliz, P; Witkowski, A; Gama Ribeiro, V; Al Abdullah, M; Weich, H; Trillo, R; Hernández García, JM; Moris, C; Jönsson, AL; Malkin, CJ; Khogali, S; Hildick Smith, D; Manoharan, G. Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis: The International FORWARD Study. J Am Coll Cardiol. 2017. 70. (7). p. 845-853. DOI: 10.1016/j.jacc.2017.06.045.
Portal de Investigación