Spanish Results of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II)

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Cano, O
  • Bellver, A
  • Fontenla, A
  • Villuendas, R
  • Penafiel, P
  • Francisco-Pascual, J
  • Ibanez, JL
  • Bertomeu-Gonzalez, V
  • Garcia-Riesco, L
  • Garcia-Seara, J
  • Martinez-Brotons, A
  • Campos, B
  • Enero, J
  • Pelaez, A
  • Martinez-Ferrer, J
  • Mazuelos, F
  • Morinigo, JL
  • Exposito, C
  • Arenal, A
  • Pombo, M
  • Segura, F
  • Pastor, A
  • Perez, F
  • Fernandez-Lozano, I
  • Gonzalez-Ferrer, JJ
  • Moreno, S
  • Martin-Fernandez, J
  • Ormaetxe, J
  • Pavon, R
  • Tolosana, JM
  • Merce, J
  • Garcia-Almagro, FJ
  • Macias, A
  • Peinado, R
  • Linde, C
  • Normand, C
  • Dickstein, K

Grupos y Plataformas

Abstract

Introduction and objectives: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. Methods: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. Results: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P = .00003. In Spanish centers, there was a lower proportion of patients >= 75 years (27.9% vs 32.4%; P = .0071), a higher proportion in New York Heart Association functional class II (46.9% vs 36.9%; P < .00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P < .00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8 +/- 8.5 days vs 6.4 +/- 11.6; P < .00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%; P < .00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). Conclusions: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged >= 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring. (C) 2018 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
1020-1030
PubMed:
30935899

Citas Recibidas en Web of Science: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Heart failure; Cardiac resynchronization therapy

Cita

Compartir