Ablation of Rotor Domains Effectively Modulates Dynamics of Human Long-Standing Persistent Atrial Fibrillation
Fecha de publicación:
Autores con afiliación ISPA
Grupos y Plataformas
Abstract
Background: In human long-standing persistent atrial fibrillation, rotors potentially explain atrial fibrillation maintenance, but their ablation remains controversial. We aimed to explore original phase/frequency mapping methods to locate rotors and track changes induced by their ablation. Methods and Results: Thirteen patients with long-standing persistent atrial fibrillation (duration, 12-72 months) underwent phase/frequency mapping (Hilbert/Fourier transforms; CARTO-Finder) of the left and right atria (PentaRay catheter). A rotor domain was defined as an area displaying at least 3 consecutive rotations. Ablation was performed by circumferential pulmonary vein isolation plus linear ablation of extrapulmonary rotor domains. We identified 19 rotor domains in 10 patients (1.81.1 per patient; 7 in the right atrium versus 12 in the left atrium; 15 extrapulmonary). Overall, rotor domains (9.2 +/- 2.2 rotations) displayed higher frequency of activation (6.41 Hz; 95% confidence interval, 6.24-6.57) than nonrotor domains (6.17 Hz; 95% confidence interval, 6.1-6.23; P=0.021), with interatrial frequency gradients established by the spatial location of the rotor domain (P=0.016). Fibrillatory conduction was suggested as a decrease in the frequency of the slower atria after ablation close to main interatrial conduction fascicles (P=0.035). Ablation of rotor domains (ablation line, 3.5 +/- 0.9 cm) effectively decreased the frequency of activation in both ipsilateral and contralateral atria (P<0.05 for both), whereas ablation of nonrotor domains did not. Acute conversion to sinus rhythm was observed in 2 patients after ablation of rotor domains. At 1-year follow-up, 70% remained in sinus rhythm (85% out-of-antiarrhythmic drugs). Conclusions: Rotor domains appropriately explain long-standing persistent atrial fibrillation physiology at its frequency content. Their ablation effectively modifies dynamics on restricted ablation.
Datos de la publicación
- ISSN/ISSNe:
- 1941-3149, 1941-3084
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 29254947
Circulation-Arrhythmia and Electrophysiology LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 26
Citas Recibidas en Scopus: 9
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- atrial fibrillation; follow-up studies; humans; physiology; rotation
Cita
Calvo, D; Rubin, J; Perez, D; Moris, C. Ablation of Rotor Domains Effectively Modulates Dynamics of Human Long-Standing Persistent Atrial Fibrillation. Circ.-Arrhythmia Electrophysiol. 2017. 10. (12). e005740. DOI: 10.1161/CIRCEP.117.005740.
Portal de Investigación