Background: The durability of aortic valve bioprosthesis and the structural valve deterioration (SVD) are could be treated with valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI). This technique has been proven to be a feasible procedure with good results in selected patients. The aim of this work was to assess the long-term results of this TAVI with an autoexpandable valve in patients with failed Mitroflow (MF) bioprosthetic aortic valves. Methods: Single center, observational and prospective study that included 65 consecutive patients with symptomatic failed MF bioprosthetic aortic valve, treated with VIV-TAVI. The primary endpoints were clinical long-term events including all-cause mortality; cardiovascular mortality, re-hospitalization due to heart failure, stroke/transient ischemic attack (TIA) and endocarditis. Secondary endpoints were the absence of SVD or patient-prosthesis mismatch (PPM) and valve hemodynamics analysis at follow-up. Results: Between March 2012 to July 2019, 65 symptomatic patients (age 80.4 +/- 5.9 years) with degenerated MF valves (numbers 19: 27.7%; 21: 38.5%; 23: 21.5%; 25: 12.3%) underwent CoreValve (n=11) or Evolut R (n=54) implantation (23, 26 and 29 mm sizes). The STS predicted risk of mortality was 6.39%+/- 5.62%. The primary combined endpoint occurred in 32.3% of the cases. A total of 13 patients (20%) died during follow-up, but 4 (7.3%) from cardiovascular causes. Two patients were reported of having a stroke/TIA and 5 readmissions for cardiovascular causes were reported (2 of them within the first 30 days). liventy-five patients (38.5%) presented PPM during follow-up, being PPM severe in 15 (23.1%). Conclusions: Self-expanding TAVI for degenerated MF bioprosthesis has favourable long-term outcomes. It is a good option in order to avoid the risks of redo surgery in selected patients.

Datos de la publicación

ISSN/ISSNe:
2305-5839, 2305-5847

Annals of Translational Medicine  AME PUBL CO

Tipo:
Article
Páginas:
-
PubMed:
32953755

Citas Recibidas en Web of Science: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Long-term; Mitroflow (MF); valve-in-valve (VIV); transcatheter aortic valve implantation (TAVI); degeneration

Cita

Compartir