Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials)
Autores con afiliación ISPA
Otros autores
- Alfonso, F
- Perez-Vizcayno, MJ
- del Blanco, BG
- Garcia-Touchard, A
- Masotti, M
- Lopez-Minguez, JR
- Iniguez, A
- Zueco, J
- Velazquez, M
- Cequier, A
- Lazaro-Garcia, R
- Marti, V
- Urbano-Carrillo, C
- Bastante, T
- Rivero, F
- Cardenas, A
- Gonzalo, N
- Jimenez-Quevedo, P
- Fernandez, C
Abstract
Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 +/- 0.5 vs 2.12 +/- 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 +/- 0.7 vs 1.88 +/- 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 +/- 0.6 vs 1.00 +/- 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 +/- 21% vs 28 +/- 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p = 0.01, hazard ratio 0.46, 95% CI 0.25 to 0.86). This pooled analysis of the RIBS IV and RIBS V randomized trials demonstrates the superiority of EES over DEB in the treatment of patients with ISR. (C) 2016 Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0002-9149, 1879-1913
- Tipo:
- Article
- Páginas:
- 546-554
- PubMed:
- 26725102
- Enlace a otro recurso:
- www.scopus.com
AMERICAN JOURNAL OF CARDIOLOGY EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 19
Citas Recibidas en Scopus: 16
Documentos
- No hay documentos
Filiaciones
Keywords
- everolimus; paclitaxel; everolimus; immunosuppressive agent; aged; angiocardiography; Article; comparative study; controlled study; coronary artery recanalization; drug delivery device; drug eluting balloon; everolimus eluting coronary stent; female; follow up; heart death; heart infarction; human; in-stent restenosis; major clinical study; male; multicenter study; priority journal; randomized controlled trial; clinical trial; coronary angiography; Coronary Restenosis; devices; drug eluting stent; Graft Occlusion, Vascular; percutaneous coronary intervention; procedures; prospective study; prosthesis design; radiography; time factor; transluminal coronary angioplasty; treatment outcome; Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Graft Occlusion, Vascular; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Time Factors; Treatm
Cita
Alfonso, F; Perez Vizcayno, MJ; del Blanco, BG; Garcia Touchard, A; Masotti, M; Lopez Minguez, JR; Iniguez, A; Zueco, J; Velazquez, M; Cequier, A; Lazaro Garcia, R; Marti, V; Moris, C; Urbano Carrillo, C; Bastante, T; Rivero, F; Cardenas, A; Gonzalo, N; Jimenez Quevedo, P; Fernandez, C. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials). Am J Cardiol. 2016. 117. (4). p. 546-554. DOI: 10.1016/j.amjcard.2015.11.042.
Portal de Investigación