Percutaneous Implantation of the CoreValve (R) Self-expanding Valve Prosthesis in Patients With Severe Aortic Stenosis and Porcelain Aorta: Medium-term Follow-up

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Munoz-Garcia, AJ
  • Lopez-Otero, D
  • Jimenez-Navarro, MF
  • Cid-Alvarez, B
  • Alonso-Briales, JH
  • Ocaranza-Sanchez, R
  • Alfonso, F
  • Hernandez, JM
  • Trillo-Nouche, R

Abstract

Introduction and objectives: There is little information on the use of transcatheter aortic valve implantation in patients with severe aortic stenosis and porcelain aorta. The primary aim of this study was to analyze death from any cause after CoreValve W implantation in patients with severe aortic stenosis, with and without porcelain aorta. Methods: In this multicenter, observational prospective study, carried out in 3 hospitals, percutaneous aortic valves were implanted in 449 patients with severely calcified aortic stenosis. Of these, 36 (8%) met the criteria for porcelain aorta. The primary end-point was death from any cause at 2 years. Results: Patients with porcelain aorta more frequently had extracardiac vascular disease (11 [30.6%] vs 49 [11.9%]; P=.002), prior coronary revascularization (15 [41.7%] vs 98 [23.7%]; P=.017), and dyslipidemia (26 [72.2%] vs 186 [45%]; P=.02). In these patients, there was greater use of general anesthesia (15 [41.7%] vs 111 [16.9%]; P=.058) and axillary access (9 [25%] vs 34 [8.2%]; P=. 004). The success rate of the procedure (94.4 vs 97.3%; P=.28) and the incidence of complications (7 [19.4%] vs 48 [11.6%]; P=. 20) were similar in both groups. There were no statistically significant differences in the primary end point at 24 months of follow-up (8 [22.2%] vs 66 [16%]; P=.33). The only predictive variable for the primary end point was the presence of complications during implantation (hazard ratio= 2.6; 95% confidence interval, 1.54.5; P=.001). Conclusions: In patients with aortic stenosis and porcelain aorta unsuitable for surgery, percutaneous implantation of the CoreValve W self-expanding valve prosthesis is safe and feasible. (C) 2013 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0300-8932, 1579-2242

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
775-781
PubMed:
24773857
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 22

Citas Recibidas en Scopus: 21

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Porcelain aorta; CoreValve (R); Aortic stenosis

Cita

Compartir