Posterior chamber phakic intraocular lens with central-port design in 45-to 55-year-old patients: 1-year follow-up
Autores con afiliación ISPA
Otros autores
- Lisa, C
- Fernandez-Vega-Cueto, L
- Besteiro, J
- Alfonso-Bartolozzi, B
Grupos y Plataformas
Abstract
Purpose: To assess the efficacy, safety, and predictability of the Visian implantable collamer lens with a central port in patients aged between 45 and 55 years. Setting: Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design: Retrospective case series. Methods: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), vault, and adverse events over a 1-year period were evaluated retrospectively. Results: A total of 87 eyes (49 patients) were evaluated. The mean postoperative UDVA and CDVA were 0.82 +/- 0.24 and 0.93 +/- 0.12, respectively. Seventy-eight eyes (approximately 90%) achieved a CDVA of 20/25 or greater. No eye lost 1 or more lines, 53 eyes (60.92%) did not change, 15 eyes (17.24%) gained 1 line, and 19 eyes (21.84%) gained 2 lines or more of CDVA. The efficacy and safety indexes were 0.95 and 1.08, respectively. Seventy-eight eyes (89.65%) were within +/- 0.50 diopter (D) of the desired sphere refraction, and all eyes (100%) were within +/- 1.00 D. Fifty eyes (57.7%) showed a spherical equivalent within +/- 0.13 D. The mean postoperative IOP was 13.58 +/- 1.79 mm Hg, and no significant rise (>18mmHg) occurred during the follow-up. The largest proportion of eyes (35.63%) reported a reduction in IOP by 1 to 2 mm Hg. Postoperative mean ECD was 2574 +/- 362 cells/mm(2) (0.41% loss from the preoperative baseline). The mean postoperative vault was 398 +/- 187 mm, being the most prevalent range from 201 to 300 mm (22.89% of eyes). No adverse events were reported during the study. Conclusions: The outcomes reported in this study support the use of this lens in older patients.
Datos de la publicación
- ISSN/ISSNe:
- 0886-3350, 1873-4502
- Tipo:
- Article
- Páginas:
- 459-464
- PubMed:
- 33181625
JOURNAL OF CATARACT AND REFRACTIVE SURGERY LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Cita
Alfonso, JF; Lisa, C; Fernandez Cueto, L; Besteiro, J; Alfonso Bartolozzi, B. Posterior chamber phakic intraocular lens with central-port design in 45-to 55-year-old patients: 1-year follow-up. J. Cataract. Refract. Surg. 2021. 47. (4). p. 459-464. DOI: 10.1097/j.jcrs.0000000000000486.
Portal de Investigación