Atrioventricular Conduction Disturbance Characterization in Transcatheter Aortic Valve Implantation With the CoreValve Prosthesis
Autores con afiliación ISPA
Otros autores
- Renilla, A
- Rios, E
- Anguera, I
- Cequier, A
Abstract
Background-Atrioventricular (AV) block is one of the most frequent complications of CoreValve transcatheter aortic valve implantation (TAVI). The aim of this study was to analyze the effects of CoreValve implantation on AV conduction. Methods and Results-Electrophysiological study was performed immediately before and after CoreValve implantation in 18 consecutive, permanent pacemaker-free patients. An electrode was placed on the His bundle during valve implantation, and data were continuously recorded during the procedure. With surface ECG, a median (first, third quartile) QRS width of 96 (84, 116) to 150 (121, 164) ms (P = 0.001) and PR interval of 180 (159, 216) to 210 (190, 240) ms (P = 0.008) were significantly prolonged, and QRS axis was left deviated 30 degrees (-32 degrees, 46 degrees) to -20 degrees (-60 degrees, 2 degrees) (P = 0.005). With intracardiac electrograms, the AII (97 [70, 123] to 115 [96, 135] ms, P = 0.021) and HV (52 [42, 55] to 60 [50, 70] ms, P = 0.002) intervals were increased. At the end of the procedure, we observed significant ECG-or electrophysiological study-persistent conduction disturbances in 14 (78%) patients. Five patients experienced transient changes (2 AV blocks and 3 left bundle branch blocks). Conclusions-CoreValve implantation worsens AV conduction in most patients, either transiently or permanently. This worsening is the result of direct damage either on the His bundle or on the AV node. (Circ Cardiovasc Interv. 2011;4:280-286.)
Datos de la publicación
- ISSN/ISSNe:
- 1941-7640, 1941-7632
- Tipo:
- Article
- Páginas:
- 280-286
- PubMed:
- 21540440
- Enlace a otro recurso:
- www.scopus.com
Circulation-Cardiovascular Interventions LIPPINCOTT WILLIAMS & WILKINS
Citas Recibidas en Web of Science: 65
Citas Recibidas en Scopus: 50
Documentos
- No hay documentos
Filiaciones
Keywords
- aortic valve; heart valve prosthesis implantation; stenosis; atrioventricular block; electrophysiology; pacemakers
Cita
Rubin, JM; Avanzas, P; del Valle, R; Renilla, A; Rios, E; Calvo, D; Lozano, I; Anguera, I; Diaz Molina, B; Cequier, A; de la Tassa, CM. Atrioventricular Conduction Disturbance Characterization in Transcatheter Aortic Valve Implantation With the CoreValve Prosthesis. Circ Cardiovasc Interv. 2011. 4. (3). p. 280-286. DOI: 10.1161/CIRCINTERVENTIONS.111.961649.
Portal de Investigación