A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis - Results of the restenosis intrastent: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial
Autores con afiliación ISPA
Otros autores
- Alfonso, F
- Perez-Vizcayno, MJ
- Hernandez, R
- Bethencourt, A
- Marti, V
- Lopez-Minguez, JR
- Angel, J
- Mantilla, R
- Cequier, A
- Sabate, M
- Escaned, J
- Moreno, R
- Banuelos, C
- Suarez, A
- Macaya, C
- RIBS-II Investigators
Abstract
OBJECTIVES We sought to assess the effectiveness of sirolimus-eluting stents (SES) in patients with in-stent restenosis (ISR). BACKGROUND Treatment of patients with ISR remains a challenge. METHODS The Restenosis Intrastent: Balloon Angioplasty Versus Elective Sirotimus-Eluting Stenting (RIBS-II) study is a multicenter randomized trial conducted in 150 patients with ISR (76 allocated to SES and 74 to balloon angioplasty [BA]). The primary end point was recurrent restenosis rate at nine months. Secondary end points included prespecified subgroup analysis, lumen volume on intravascular ultrasound (IVUS), and a composite of major clinical events at one year. RESULTS Angiographic success was obtained in all patients. At 9-month angiographic follow-up (96% of eligible patients) minimal lumen diameter was larger (2.52 mm [interquartile range (IQR) 2.09 to 2.81] vs. 1.54 mm [IQR 0.91 to 2.05]; p < 0.001) and recurrent restenosis rate was lower (11% vs. 39%; p < 0.001) in the SES group. Prespecified subgroup analyses were consistent with the main outcome measure. Lumen volume on IVUS at 9 months was also larger (279 mm(3) [IQR 227 to 300] vs. 197 mm(3) [IQR 177 to 230]; p < 0.001) in the SES group. At one-year clinical follow-up (100% of patients), the event-free survival (freedom from death, myocardial infarction, and target vessel revascularization) was significantly improved in the SES group (88% vs. 69%; p < 0.004) as the result of a lower requirement for target vessel revascularization (11% vs. 30%; p < 0.003). CONCLUSIONS In patients with ISR, the use of SES provides superior long-term clinical, angiographic, and IVUS outcome than BA treatment.
Datos de la publicación
- ISSN/ISSNe:
- 0735-1097, 1558-3597
- Tipo:
- Article
- Páginas:
- 2152-2160
- PubMed:
- 16750678
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 135
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Cita
Alfonso, F; Perez Vizcayno, MJ; Hernandez, R; Bethencourt, A; Marti, V; Lopez Minguez, JR; Angel, J; Mantilla, R; Moris, C; Cequier, A; Sabate, M; Escaned, J; Moreno, R; Banuelos, C; Suarez, A; Macaya, C; RIBS II, I. A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis - Results of the restenosis intrastent: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial. J Am Coll Cardiol. 2006. 47. (11). p. 2152-2160. DOI: 10.1016/j.jacc.2005.10.078.
Portal de Investigación