Multicenter Performance Evaluation of MALDI-TOF MS for Rapid Detection of Carbapenemase Activity in Enterobacterales: The Future of Networking Data Analysis With Online Software
Fecha de publicación:
Autores con afiliación ISPA
Otros autores
- Gato, Eva
- Anantharajah, Ahalieyah
- Arroyo, Manuel J.
- Artacho, Maria Jose
- Caballero, Juan de Dios
- Candela, Ana
- Chudejova, Katerina
- Constanso, Ignacio Pedro
- Elias, Cristina
- Jimenez, Jesus
- Mendez, Gema
- Mulet, Xavier
- Perez-Palacios, Patricia
- Rodriguez-Sanchez, Belen
- Canton, Rafael
- Hrabak, Jaroslav
- Mancera, Luis
- Martinez-Martinez, Luis
- Oliver, Antonio
- Pascual, Alvaro
- Verroken, Alexia
- Bou, German
- Oviano, Marina
Grupos y Plataformas
Abstract
In this study, we evaluate the performance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for rapid detection of carbapenemase activity in Enterobacterales in clinical microbiology laboratories during a multicenter networking validation study. The study was divided into three different stages: ``software design,'' ``intercenter evaluation,'' and ``clinical validation.'' First, a standardized procedure with an online software for data analysis was designed. Carbapenem resistance was detected by measuring imipenem hydrolysis and the results were automatically interpreted using the Clover MS data analysis software (Clover BioSoft, Spain). Second, a series of 74 genotypically characterized Enterobacterales (46 carbapenemase-producers and 28 non carbapenemase-producers) were analyzed in 8 international centers to ensure the reproducibility of the method. Finally, the methodology was evaluated independently in all centers during a 2-month period and results were compared with the reference standard for carbapenemase detection used in each center. The overall agreement rate relative to the reference method for carbapenemase resistance detection in clinical samples was 92.5%. The sensitivity was 93.9% and the specificity, 100%. Results were obtained within 60 min and accuracy ranged from 83.3 to 100% among the different centers. Further, our results demonstrate that MALDI-TOF MS is an outstanding tool for rapid detection of carbapenemase activity in Enterobacterales in clinical microbiology laboratories. The use of a simple in-house procedure with online software allows routine screening of carbapenemases in diagnostics, thereby facilitating early and appropriate antimicrobial therapy.
Datos de la publicación
- ISSN/ISSNe:
- 1664-302X, 1664-302X
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 35154029
Frontiers in Microbiology FRONTIERS MEDIA SA
Citas Recibidas en Web of Science: 4
Documentos
- No hay documentos
Filiaciones
Keywords
- MALDI-TOF MS; carbapenemases enzymes; resistance detection; imipenem; clinical microbiology
Cita
Gato, E; Anantharajah, A; Arroyo, MJ; Artacho, MJ; Caballero, JD; Candela, A; Chudejova, K; Constanso, IP; Elias, C; Fernandez, J; Jimenez, J; Lumbreras, P; Mendez, G; Mulet, X; Perez Palacios, P; Rodriguez Sanchez, B; Canton, R; Hrabak, J; Mancera, L; Martinez, L; Oliver, A; Pascual, A; Verroken, A; Bou, G; Oviano, M. Multicenter Performance Evaluation of MALDI-TOF MS for Rapid Detection of Carbapenemase Activity in Enterobacterales: The Future of Networking Data Analysis With Online Software. Front Microbiol. 2022. 12. 789731. DOI: 10.3389/fmicb.2021.789731.
Portal de Investigación