Variability of the VA interval at tachycardia induction: a simple method to differentiate orthodromic reciprocating tachycardia from atypical atrioventricular nodal reentrant tachycardia

Fecha de publicación: Fecha Ahead of Print:

Autores con afiliación ISPA

  • David Calvo Cuervo

    Autor

Otros autores

  • Hadid, Claudio
  • Celano, Leonardo
  • Di Toro, Dario
  • Antezana-Chavez, Edgar
  • Gallino, Sebastian
  • Iralde, Gustavo
  • Avila, Pablo
  • Atea, Leonardo
  • Gonzalez, Sergio
  • Maldonado, Sebastian
  • Labadet, Carlos

Grupos y Plataformas

Abstract

Background The differential diagnosis between orthodromic atrioventricular reentry tachycardia (AVRT) and atypical AV nodal reentrant tachycardia (aAVNRT) is sometimes challenging. We hypothesize that aAVNRTs have more variability in the retrograde conduction time at tachycardia onset than AVRTs. Methods We aimed to assess the variability in retrograde conduction time at tachycardia onset in AVRT and aAVNRT and to propose a new diagnostic tool to differentiate these two arrhythmia mechanisms. We measured the VA interval of the first beats after tachycardia induction until it stabilized. The difference between the maximum and minimum VA intervals (Delta VA) and the number of beats needed for the VA interval to stabilize was analyzed. Atrial tachycardiac were excluded. Results A total of 107 patients with aAVNRT (n = 37) or AVRT (n = 64) were included. Six additional patients with decremental accessory pathway-mediated tachycardia (DAPT) were analyzed separately. All aAVNRTs had VA interval variability. The median Delta VA was 0 (0 - 5) ms in AVRTs vs 40 (21 - 55) ms in aAVNRTs (p < 0.001). The VA interval stabilized significantly earlier in AVRTs (median 1.5 [1- 3] beats) than in aAVNRTs (5 [4 - 7] beats; p < 0.001). A Delta VA <10 ms accurately differentiated AVRT from aAVNRT with 100% of sensitivity, specificity, and positive and negative predictive values. The stabilization of the VA interval at <3 beats of the tachycardia onset identified AVRT with sensitivity, specificity, and positive and negative predictive values of 64.1%, 94.6%, 95.3%, and 60.3%, respectively. A Delta VA< 20 ms yielded good diagnostic accuracy for DAPT. Conclusions A Delta VA <10 ms is a simple and useful criterion that accurately distinguished AVRT from atypical AVNRT.

Datos de la publicación

ISSN/ISSNe:
1383-875X, 1572-8595

JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY  SPRINGER

Tipo:
Article
Páginas:
-
PubMed:
36152135

Citas Recibidas en Web of Science: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Supraventricular tachycardia; VA interval; Orthodromic AV reentry tachycardia; Atypical AV nodal reentry tachycardia; Decremental accessory pathway

Cita

Compartir