Temporal trend and potential impact of angiotensin receptor neprilysin inhibitors on transcatheter edge-to-edge mitral valve repair
Autores con afiliación ISPA
Otros autores
- Barrero, Alejandro
- Carrasco-Chinchilla, Fernando
- Benito-Gonzalez, Tomas
- Arzamendi, Dabit
- Estevez-Loureiro, Rodrigo
- Nombela-Franco, Luis
- Pan, Manuel
- Freixa, Xavier
- Trillo-Nouche, Ramiro
- Sanchez-Recalde, Angel
- Andraka, Leire
- Cruz-Gonzalez, Ignacio
- Ramon Lopez-Minguez, Jose
- Diez Gil, Jose Luis
- Urbano-Carrillo, Cristobal
- Sanmiguel Cervera, Dario
- Sanchis, Juan
- Bosa, Francisco
- Ruiz, Valeriano
- Del Trigo, Maria
- Molina, Eduardo
- Serrador, Ana M.
- Alonso-Briales, Juan H.
- Garrote, Carmen
- Li, Chi Hion
- Antonio Baz, Jose
- Jimenez-Quevedo, Pilar
- Mesa, Dolores
- Regueiro, Ander
- Cid, Belen
- Carrasco-Moraleja, Manuel
- Rodriguez-Gabella, Tania
- Hernandez-Garcia, Jose M.
- Fernandez-Vazquez, Felipe
- Amat-Santos, Ignacio J.
- Spanish TEER Grp
Grupos y Plataformas
Abstract
Introduction and objectives: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. Methods: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n = 450) and b) TEER after the recommendation of ARNIs by European Guidelines (n = 639), with further analysis according to intake (n = 52) or not (n = 587) of ARNIs. Results: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82 mL vs 100 mL, P = .025), and better function (35% vs 38%, P = .011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P < .001) and heart failure readmissions (16.6% vs 27.8%, P < .001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1-and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission + mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P = .048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P = .011). Conclusions: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence. (c) 2022 Sociedad Espantola de Cardiologa. Published by Elsevier Espanta, S.L.U. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 1885-5857, 1885-5857
- Tipo:
- Article
- Páginas:
- 1001-1010
- PubMed:
- 35272968
REVISTA ESPANOLA DE CARDIOLOGIA EDICIONES DOYMA S A
Documentos
- No hay documentos
Filiaciones
Keywords
- TEER; MitraClip; Pascal; Sacubitril/valsartan; ARNIs; Mitral regurgitation
Cita
Barrero, A; Carrasco Chinchilla, F; Benito Gonzalez, T; Pascual, I; Arzamendi, D; Estevez Loureiro, R; Nombela Franco, L; Pan, M; Freixa, X; Trillo Nouche, R; Sanchez Recalde, A; Andraka, L; Cruz Gonzalez, I; Ramon Lopez Minguez, J; Diez Gil, JL; Urbano Carrillo, C; Sanmiguel Cervera, D; Sanchis, J; Bosa, F; Ruiz, V; Del Trigo, M; Molina, E; Serrador, AM; Alonso Briales, JH; Garrote, C; Avanzas, P; Li, CH; Antonio Baz, J; Jimenez Quevedo, P; Mesa, D; Regueiro, A; Cid, B; Carrasco Moraleja, M; Rodriguez Gabella, T; Hernandez Garcia, JM; Fernandez Vazquez, F; Amat Santos, IJ; Spanish TEER, GRP. Temporal trend and potential impact of angiotensin receptor neprilysin inhibitors on transcatheter edge-to-edge mitral valve repair. Rev Esp Cardiol (Engl Ed). 2022. 75. (12). p. 1001-1010. DOI: 10.1016/j.rec.2022.02.001.
Portal de Investigación