Self-expanding TAVI using the cusp overlap technique versus the traditional technique: electrocardiogram changes and 1-year cardiovascular outcomes.

Fecha de publicación: Fecha Ahead of Print:

Autores con afiliación ISPA

Otros autores

  • Persia-Paulino, Yvan R
  • Almendarez Lacayo, Marcel
  • Fernandez Asensio, Rodrigo
  • Cuevas Perez, Javier
  • Vigil-Escalera, Maria
  • Alvarez Velasco, Rut
  • Renilla, Alfredo
  • Del Valle Fernandez, Raquel

Grupos y Plataformas

Abstract

Introduction and objectives: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up. Methods: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year. Results: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P = .002) and less P wave (13.1 +/- 21.0 msec vs 5.47 +/- 12.5 msec; P = .003) and QRS prolongation (29.77 +/- 27.0 msec vs 16.38 +/- 25.4 msec, P < .001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P = .005). Conclusions: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.

Datos de la publicación

ISSN/ISSNe:
1885-5857, 1885-5857

REVISTA ESPANOLA DE CARDIOLOGIA  EDICIONES DOYMA S A

Tipo:
Article
Páginas:
29-38
PubMed:
37437882

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Keywords

  • Transcatheter aortic valve replacement; Valve implantation; Pacemaker; Artificial cardiac pacing; Cardiovascular adverse effects; Electrocardiography