Self-expanding TAVI using the cusp overlap technique versus the traditional technique: electrocardiogram changes and 1-year cardiovascular outcomes.
Autores con afiliación ISPA
Otros autores
- Persia-Paulino, Yvan R
- Almendarez Lacayo, Marcel
- Fernandez Asensio, Rodrigo
- Cuevas Perez, Javier
- Vigil-Escalera, Maria
- Alvarez Velasco, Rut
- Renilla, Alfredo
- Del Valle Fernandez, Raquel
Grupos y Plataformas
Abstract
Introduction and objectives: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up. Methods: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year. Results: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P = .002) and less P wave (13.1 +/- 21.0 msec vs 5.47 +/- 12.5 msec; P = .003) and QRS prolongation (29.77 +/- 27.0 msec vs 16.38 +/- 25.4 msec, P < .001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P = .005). Conclusions: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.
Datos de la publicación
- ISSN/ISSNe:
- 1885-5857, 1885-5857
- Tipo:
- Article
- Páginas:
- 29-38
- PubMed:
- 37437882
REVISTA ESPANOLA DE CARDIOLOGIA EDICIONES DOYMA S A
Documentos
- No hay documentos
Filiaciones
Filiaciones no disponibles
Keywords
- Transcatheter aortic valve replacement; Valve implantation; Pacemaker; Artificial cardiac pacing; Cardiovascular adverse effects; Electrocardiography
Cita
Persia Paulino, YR; Almendarez Lacayo, M; Alperi, A; Hernandez Vaquero, D; Fernandez Asensio, R; Cuevas Perez, J; Adeba, A; Florez, P; Vigil Escalera, M; Alvarez Velasco, R; Renilla, A; Del Valle Fernandez, R; Antuna, P; Moris de la Tassa, C; Avanzas, P; Pascual, I. Self-expanding TAVI using the cusp overlap technique versus the traditional technique: electrocardiogram changes and 1-year cardiovascular outcomes. Rev Esp Cardiol (Engl Ed). 2023. 77. (1). p. 29-38. DOI: 10.1016/j.rec.2023.04.008.
Portal de Investigación