Applicability of the Barcelona scale to assess the quality of cleanliness of mucosa at esophagogastroduodenoscopy.

Fecha de publicación: Fecha Ahead of Print:

Autores con afiliación ISPA

Otros autores

  • Cordova, Henry
  • Castillo-Regalado, Edgar
  • Cubiella, Joaquin
  • Delgado-Guillena, Pedro
  • Diez Redondo, Pilar
  • Galdin, Martin
  • Garcia-Rodriguez, Ana
  • Hernandez, Luis
  • Huerta, Alain
  • Jover, Rodrigo
  • Nunez, Henar
  • Rodriguez-D'Jesus, Antonio
  • Seoane, Agustin
  • Suris, Gerard
  • Jimenez Sanchez, Javier
  • Martin, Francisco
  • Moreira, Leticia
  • Carballal, Sabela
  • Rivero, Liseth
  • Da Fieno, Angella
  • Casanova, Gherzon
  • Luzko Scheid, Irina
  • Llach, Joan
  • Fernandez-Esparrach, Gloria

Grupos y Plataformas

Abstract

BACKGROUND AND OBJECTIVES: There are few scales with prospective validation for the assessment of the upper gastrointestinal mucosal cleanliness during an esophagogastroduodenoscopy (EGD). The aim of this study was to develop a valid and reproducible cleanliness scale for use during an EGD.; METHODS: We developed a cleanliness scale (Barcelona scale) with a score (0-2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times.; RESULTS: In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45-0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45-0.93). The intra-observer variability was 0.89 (0.76-0.99).; CONCLUSIONS: The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD. Copyright © 2023 Elsevier Espana, S.L.U. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0210-5705, 0210-5705

Gastroenterologia y Hepatologia  ELSEVIER ESPANA SLU

Tipo:
Article
Páginas:
246-252
PubMed:
37236304
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 17

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Keywords

  • Quality; Esophagogastroduo- denoscopy; Cleanliness

Cita

Compartir