Safety and Efficacy of TAVR With a Pressure Sensor and Pacing Guidewire SAFE-TAVI Trial

Fecha de publicación: Fecha Ahead of Print:

Autores con afiliación ISPA

Otros autores

  • Regueiro, A
  • Vilalta, V
  • Asmarats, L
  • Baz, JA
  • Nombela-Franco, L
  • Calabuig, A
  • Muñoz-García, A
  • Sabaté, M
  • Picard-Deland, M
  • Pelletier-Beaumont, E
  • Rodés-Cabau, J

Grupos y Plataformas

Abstract

BACKGROUND The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring.OBJECTIVES This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures.METHODS This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire.RESULTS A total of 121 patients (mean age: 82.2 +/- 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary effi-cacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 +/- 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported.CONCLUSIONS The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment.

Datos de la publicación

ISSN/ISSNe:
1936-8798, 1876-7605

JACC-Cardiovascular Interventions  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
3016-3023
PubMed:
37902144

Citas Recibidas en Web of Science: 1

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • aortic stenosis; hemodynamic assessment; left ventricular pacing; transcatheter aortic valve replacement