Abstract
Skin corrosion testing is integral to evaluating the potential harm posed by chemicals, impacting regulatory decisions on safety, transportation, and labeling. Traditional animal testing methods are giving way to in vitro alternatives, such as reconstructed human epidermis (RhE) models, aligning with evolving ethical standards. This study evaluates the QileX-RhE test system ' s performance for chemical subcategorization within the OECD TG 431 framework. Results demonstrate its ability to differentiate subcategories, accurately predicting 83% of UN GHS Category 1A and 73% of UN GHS Category 1B/1C chemicals with 100% sensitivity in corrosive prediction. Additionally, this study provides a comprehensive assessment of the test method ' s performance by employing nuanced parameters such as positive predictive value (PPV), negative predictive value (NPV), post -test odds and likelihood rations, offering valuable insights into the applicability and effectiveness of the QileX-RhE test method.
Datos de la publicación
- ISSN/ISSNe:
- 0887-2333, 1879-3177
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 38604524
TOXICOLOGY IN VITRO PERGAMON-ELSEVIER SCIENCE LTD
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- Skin corrosion testing; QileX-RhE; OECD TG 431; Skin corrosivity assessment; Alternative testing methods; Predictive capacity; Chemical safety evaluation
Cita
Chacón, M; Vázquez, N; Alonso, S; Llames, S; Pevida, M; Alcalde, I; Merayo Lloves, J; Meana, A. Evaluating the QileX-RhE skin corrosion test for chemical subcategorization in accordance with OECD TG 431. Toxicol In Vitro. 2024. 98. 105816. DOI: 10.1016/j.tiv.2024.105816.
Portal de Investigación