Hemodynamic Performance of Self-Expandable Transcatheter Aortic Valve Replacement Systems During Valve Deployment
Autores con afiliación ISPA
Otros autores
- del Valle, R
- Antuna, P
- Almendárez, M
- Betanzos, JL
- Rodés-Cabau, J
Grupos y Plataformas
Abstract
Objectives Little is known about valve hemodynamic performance during the Evolut and ACURATE Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and ACURATE Neo (Boston Scientific) systems. Methods This was a single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or ACURATE Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. Results Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P < .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P < .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). Conclusions Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.
Datos de la publicación
- ISSN/ISSNe:
- 1042-3931, 1557-2501
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 38489568
JOURNAL OF INVASIVE CARDIOLOGY H M P COMMUNICATIONS
Citas Recibidas en Web of Science: 2
Documentos
- No hay documentos
Filiaciones
Keywords
- Self-Expandable; Transcatheter; Aortic stenosis; Transcatheter Aortic Valve Replacement (TAVR); Self-Expandable; Transcatheter; Heart Valve; Valve Hemodynamic Performance; Transcatheter Heart valve; Aortic stenosis
Cita
Alperi, A; Moris, C; del Valle, R; Pascual, I; Antuna, P; Almendárez, M; Hernández Vaquero, D; Betanzos, JL; Rodés Cabau, J; Avanzas, P. Hemodynamic Performance of Self-Expandable Transcatheter Aortic Valve Replacement Systems During Valve Deployment. J. Invasive Cardiol. 2024. 36. (8). 00286. DOI: 10.25270/jic/23.00286.
Portal de Investigación