One-year evaluation of automated insulin delivery systems in adults with type 1 diabetes
Fecha de publicación:
Fecha Ahead of Print:
Autores con afiliación ISPA
Grupos y Plataformas
Abstract
Introduction This study evaluates the effectiveness of four commercially available automated insulin delivery (AID) systems in routine clinical practice for type 1 diabetes management and compares their first-year outcomes.Materials This retrospective study (October 2020-October 2023) included glucometric data from type 1 diabetes patients collected from the Asturias Automatic Insulin Devices Registry. People with type 1 diabetes using four different AID systems [Minimed (TM) 780G (MM780G), Accu-Chek (R) Insight-Diabeloop (DBLG), Tandem-Control-IQ, and Ypsopump Cambridge HCL-app (Cam-APS)] were included in the study. Primary outcomes were glycaemic control after one year. Secondary outcomes compared the results between the four systems.Results 174 patients (60: MM780G, 45: DBLG, 30: Control-IQ, 39: Cam-APS), aged 18-73, predominantly women, were enrolled. At baseline, glycemic control, measured by the achievement of the international consensus targets [TBR (Time Below Range) <4%; TIR(Time in Range) >70% and TAR (Time Above Range) <25%] was only met by 9.72% of participants, while after 1 year of an AID system use, it improved to more than 52%. When comparing between systems, TIR improved significantly after 1 year in all systems. However, Control-IQ did not show improvement in mean glucose and Glucose management index (GMI) and only users of DBLG showed improvement in coefficient of variation (CV). MM780G users achieved the best results after 12 months in mean glucose, TIR and GMI. However, their baseline situation was also better than that of the other groups.Discussion This study confirms that, after 12 months of routine clinical use, the use of commercially available automated insulin delivery (AID) systems significantly improves glycemic control in individuals with type 1 diabetes. However, the degree of improvement varies depending on the specific system used. These findings underscore the importance of selecting and optimizing AID systems individually to maximize clinical benefits in type 1 diabetes management.Discussion This study confirms that, after 12 months of routine clinical use, the use of commercially available automated insulin delivery (AID) systems significantly improves glycemic control in individuals with type 1 diabetes. However, the degree of improvement varies depending on the specific system used. These findings underscore the importance of selecting and optimizing AID systems individually to maximize clinical benefits in type 1 diabetes management.
© 2025 Pujante, García, Villa-Fernández, García-Villarino, González-Vidal, Díaz-Naya, Gutiérrez Buey, Veiguela, Rivas-Otero, Menéndez-Torre, Delgado, Ares and Lambert.
Datos de la publicación
- ISSN/ISSNe:
- 2673-253X, 2673-253X
- Tipo:
- Article
- Páginas:
- 1596188-1596188
- PubMed:
- 40666106
- Enlace a otro recurso:
- www.scopus.com
Frontiers in Digital Health FRONTIERS MEDIA SA
Citas Recibidas en Web of Science: 5
Documentos
- No hay documentos
Filiaciones
Keywords
- automated insulin delivery; type 1 diabetes; hybrid close loop; diabetes technology; insulin
Proyectos y Estudios Clinicos
Contrato Sara Borrell 2023 - Carmen Lambert Goitia
Investigador Principal: Juan Pablo Rodrigo Tapia
CD23/00037 . Instituto de Salud Carlos III . 2024
Contrato Rio Hortega 2024 -Tomás González Vidal;Elias Delgado
Investigador Principal: Elías Delgado Álvarez
CM24/00080 . Instituto de Salud Carlos III . 2025
Endocrinología, Nutrición, Diabetes y Obesidad (ENDO)
Investigador Principal: Elías Delgado Álvarez
IDE/2024/000705 . Gobierno Principado de Asturias . 2025
Cita
Pujante, P; García, AV; Villa Fernández, E; García Villarino, M; González Vidal, T; Díaz Naya, L; Buey, GG; Veiguela, B; Rivas Otero, D; Menéndez Torre, E; Delgado, E; Ares, J; Lambert, C. One-year evaluation of automated insulin delivery systems in adults with type 1 diabetes. Front. Digit. Health. 2025. 7. p. 1596188-1596188. DOI: 10.3389/fdgth.2025.1596188.
Portal de Investigación