Early Hemodynamic Performance of the SAPIEN 3 Ultra Resilia and Evolut Valves: A Propensity-Matched Analysis
Autores con afiliación ISPA
Otros autores
- Avvedimento, M
- Mas-Peiro, S
- Aktaa, S
- Nombela-Franco, L
- Gonzalez, IC
- Franzone, A
- Campelo-Parada, F
- Urena, M
- Cepas-Guillén, P
- Tirado, G
- Laffond, AE
- Esposito, G
- Tamir, M
- Suc, G
- Mohammadi, S
- Pibarot, P
- Côté, M
- Webb, JG
- Rodés-Cabau, J
Grupos y Plataformas
Abstract
Background: Limited data are available on early hemodynamic outcomes of the balloon-expandable SAPIEN 3 Ultra Resilia (S3UR) (Edwards Lifesciences, Irvine, CA) compared with the self-expandable Evolut (Medtronic, Minneapolis, MN) transcatheter heart valves. In this study we aimed to compare the hemodynamic performance of the S3UR with contemporary Evolut platforms (Evolut PRO, PRO+, FX) in a propensity-matched study. Methods: A total of 307 patients who received an S3UR valve were matched with 488 patients who received Evolut valves (mean age, 80.1 +/- 7 years; 46.2% women). The primary end point was valve hemodynamics (aortic mean gradient, effective orifice area [EOA], severe prosthesis-patient mismatch [PPM], and moderate to severe aortic regurgitation [AR]) at 1-3 months after transcatheter aortic valve replacement. Secondary end points included clinical outcomes. Results: Evolut valves were associated with lower mean gradients (8.0 +/- 3.1 mm Hg vs 9.8 +/- 3.8 mm Hg; P < 0.001) but higher rates of residual AR (mild AR, 10.7% vs 4.1%; moderate to severe AR, 4.2% vs 1.4%; P < 0.001). EOA values and PPM rates were comparable. In patients with small aortic annulus (< 430 mm(2)), Evolut valves showed larger EOA (1.94 +/- 0.3 cm(2) vs 1.83 +/- 0.4 cm(2); P = 0.038) and lower gradients (7.8 +/- 2.4 mmHg vs 10.9 +/- 4.5 mmHg; P < 0.010). Moderate to severe AR and PPM were similar between groups. Despite comparable device success, early safety outcomes favoured the S3UR (81.8% vs 60.5%; P < 0.010 for S3UR and Evolut, respectively), because of higher rates of pacemaker implantation, atrial fibrillation, major vascular complication, and type 2-3 bleeding in the Evolut cohort. Conclusions: Evolut valves showed lower transprosthetic gradients but a higher rate of residual AR compared with the S3UR. Further studies are needed to validate these findings and investigate their effect on long-term outcomes.
Copyright © 2025 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0828-282X, 1916-7075
- Tipo:
- Article
- Páginas:
- 2407-2416
- PubMed:
- 40812524
CANADIAN JOURNAL OF CARDIOLOGY ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 4
Documentos
- No hay documentos
Filiaciones
Keywords
- Aortic stenosis; transcatheter heart valve; transcatheter aortic valve replacement; SAPIEN 3 Ultra Resilia; Evolut
Cita
Avvedimento, M; Mas Peiro, S; Aktaa, S; Nombela Franco, L; Alperi, A; Gonzalez, IC; Franzone, A; Campelo Parada, F; Urena, M; Cepas Guillén, P; Tirado, G; Avanzas, P; Laffond, AE; Esposito, G; Tamir, M; Suc, G; Mohammadi, S; Pibarot, P; Côté, M; Webb, JG; Rodés Cabau, J. Early Hemodynamic Performance of the SAPIEN 3 Ultra Resilia and Evolut Valves: A Propensity-Matched Analysis. Can J Cardiol. 2025. 41. (12). p. 2407-2416. DOI: 10.1016/j.cjca.2025.07.040.
Portal de Investigación