Conduction system pacing in TAVR patients requiring permanent pacemaker implantation.
Autores con afiliación ISPA
Otros autores
- Fischer Q
- Nuche J
- Badreddine A
- Ortiz-Lozada R
- Alperi A
- Oteo Dominguez JF
- Marco Del Castillo Á
- Llevadot J
- Veiga Fernandez G
- Sorrentino S
- Asmarats L
- Canitrot R
- Vilalta V
- Immobile Molaro M
- Muñoz-García AJ
- Rezaei E
- Calabuig A
- Serra V
- Cheema AN
- Esposito G
- Fernández Nofrerias E
- Campelo-Parada F
- Arzamendi D
- Indolfi C
- de la Torre Hernández JM
- Regueiro A
- Maneiro Melón N
- Del Trigo M
- Nombela-Franco L
- Garcia CB
- Avvedimento M
- Philippon F
- Rodés-Cabau J
Grupos y Plataformas
Abstract
BACKGROUND: Permanent pacemaker (PPM) implantation remains a common complication after transcatheter aortic valve replacement (TAVR) and is associated with poorer long-term outcomes. Conduction system pacing (CSP) has emerged as a promising alternative to reduce the negative effects of chronic pacing. OBJECTIVES: To determine whether CSP is associated with improved outcomes in patients requiring a PPM after TAVR. METHODS: Observational multicenter study including consecutive patients requiring PPM implantation within 30 days after TAVR. This population was propensity matched using a logistic regression model. The primary outcome was a composite endpoint including death and heart failure hospitalization at 1-year follow-up. Echocardiographic and ECG changes over time were secondary endpoints. RESULTS: After propensity score matching, 706 patients were included: 185(26.2%) in the CSP group and 521 (73.8%) in the RVP group. CSP was associated with a significantly lower risk of all-cause death or heart-failure hospitalization at 1 year compared to RVP (10.8% vs 20.9%; adjusted HR 0.48 [0.30-0.78]; p = 0.003). This was driven by significant reductions in both all-cause mortality (HR 0.52 [0.28-0.96]; p = 0.036) and heart-failure hospitalization (HR 0.50 [0.25-0.99]; p = 0.049). In addition, CSP was associated with a significantly shorter QRS duration at 30 days compared with RVP (121± 22 ms vs. 141± 18 ms; p < 0.001), as well as a significant improvement in LVEF at 1-year follow-up (+2.8 percentage points; p<0.001). CONCLUSIONS: In TAVR patients requiring PPM, CSP showed better 1-year clinical outcomes than RVP. Prospective randomized studies are needed to confirm longer-term benefits and refine patient selection.
Copyright © 2026. Published by Elsevier Inc.
Datos de la publicación
- ISSN/ISSNe:
- 1547-5271, 1556-3871
- Tipo:
- Article
- Páginas:
- -
- PubMed:
- 42385964
HEART RHYTHM ELSEVIER SCIENCE INC
Documentos
- No hay documentos
Filiaciones
Keywords
- all-cause mortality; conduction disturbances; conduction system pacing; heart failure hospitalization; permanent pacemaker implantation; propensity score matching; right ventricular pacing; transcatheter aortic valve replacement
Cita
Fischer, Q; Nuche, J; Badreddine, A; Ortiz Lozada, R; Alperi, A; Oteo Dominguez, JF; Marco Del Castillo, Á; Llevadot, J; Veiga Fernandez, G; Sorrentino, S; Asmarats, L; Canitrot, R; Vilalta, V; Immobile Molaro, M; Muñoz García, AJ; Rezaei, E; Calabuig, A; Serra, V; Cheema, AN; Esposito, G; Fernández Nofrerias, E; Campelo Parada, F; Arzamendi, D; Indolfi, C; de la Torre Hernández, JM; Regueiro, A; Maneiro Melón, N; Del Trigo, M; Avanzas, P; Nombela Franco, L; Garcia, CB; Avvedimento, M; Philippon, F; Rodés Cabau, J. Conduction system pacing in TAVR patients requiring permanent pacemaker implantation. Heart Rhythm. DOI: 10.1016/j.hrthm.2026.06.032.
Portal de Investigación