Conduction system pacing in TAVR patients requiring permanent pacemaker implantation.

Fecha de publicación: Fecha Ahead of Print:

Autores con afiliación ISPA

Otros autores

  • Fischer Q
  • Nuche J
  • Badreddine A
  • Ortiz-Lozada R
  • Alperi A
  • Oteo Dominguez JF
  • Marco Del Castillo Á
  • Llevadot J
  • Veiga Fernandez G
  • Sorrentino S
  • Asmarats L
  • Canitrot R
  • Vilalta V
  • Immobile Molaro M
  • Muñoz-García AJ
  • Rezaei E
  • Calabuig A
  • Serra V
  • Cheema AN
  • Esposito G
  • Fernández Nofrerias E
  • Campelo-Parada F
  • Arzamendi D
  • Indolfi C
  • de la Torre Hernández JM
  • Regueiro A
  • Maneiro Melón N
  • Del Trigo M
  • Nombela-Franco L
  • Garcia CB
  • Avvedimento M
  • Philippon F
  • Rodés-Cabau J

Grupos y Plataformas

Abstract

BACKGROUND: Permanent pacemaker (PPM) implantation remains a common complication after transcatheter aortic valve replacement (TAVR) and is associated with poorer long-term outcomes. Conduction system pacing (CSP) has emerged as a promising alternative to reduce the negative effects of chronic pacing. OBJECTIVES: To determine whether CSP is associated with improved outcomes in patients requiring a PPM after TAVR. METHODS: Observational multicenter study including consecutive patients requiring PPM implantation within 30 days after TAVR. This population was propensity matched using a logistic regression model. The primary outcome was a composite endpoint including death and heart failure hospitalization at 1-year follow-up. Echocardiographic and ECG changes over time were secondary endpoints. RESULTS: After propensity score matching, 706 patients were included: 185(26.2%) in the CSP group and 521 (73.8%) in the RVP group. CSP was associated with a significantly lower risk of all-cause death or heart-failure hospitalization at 1 year compared to RVP (10.8% vs 20.9%; adjusted HR 0.48 [0.30-0.78]; p = 0.003). This was driven by significant reductions in both all-cause mortality (HR 0.52 [0.28-0.96]; p = 0.036) and heart-failure hospitalization (HR 0.50 [0.25-0.99]; p = 0.049). In addition, CSP was associated with a significantly shorter QRS duration at 30 days compared with RVP (121± 22 ms vs. 141± 18 ms; p < 0.001), as well as a significant improvement in LVEF at 1-year follow-up (+2.8 percentage points; p<0.001). CONCLUSIONS: In TAVR patients requiring PPM, CSP showed better 1-year clinical outcomes than RVP. Prospective randomized studies are needed to confirm longer-term benefits and refine patient selection.

Copyright © 2026. Published by Elsevier Inc.

Datos de la publicación

ISSN/ISSNe:
1547-5271, 1556-3871

HEART RHYTHM  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
-
PubMed:
42385964

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • all-cause mortality; conduction disturbances; conduction system pacing; heart failure hospitalization; permanent pacemaker implantation; propensity score matching; right ventricular pacing; transcatheter aortic valve replacement

Cita

Compartir