Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement

Fecha de publicación:

Autores con afiliación ISPA

Otros autores

  • Trimaille, A
  • Cepas-Guillén, P
  • Urena, M
  • Veiga-Fernandez, G
  • Nombela-Franco, L
  • Vilalta, V
  • del Trigo, M
  • Muñoz-García, AJ
  • Esposito, G
  • Auffret, V
  • del Val, D
  • Serra, V
  • Nuche, J
  • Asmarats, L
  • Regueiro, A
  • Carmona, A
  • Fisher, Q
  • Fradejas-Sastre, V
  • Sanchez, I
  • Trichilo, M
  • Oteo, JF
  • Franzone, A
  • Nolf, M
  • Alfonso, F
  • Pockels, PD
  • Rodríguez-Santolino, R
  • Arzamendi, D
  • Flores-Umanzor, E
  • Morel, O
  • Avvedimento, M
  • Rodés-Cabau, J

Grupos y Plataformas

Abstract

BACKGROUND: Data on the long-term incidence and clinical impact of bioprosthetic valve failure (BVF) after transcatheter aortic valve replacement remain limited. This study aimed to assess the incidence, predictors, and clinical impact of BVF following transcatheter aortic valve replacement. METHODS: We analyzed data from an international, multicenter registry including consecutive patients undergoing transcatheter aortic valve replacement at 13 centers. The primary outcome was BVF according to Valve Academic Research Consortium-3 criteria. The cumulative incidence of BVF was estimated using a competing-risk approach. The association between BVF and clinical outcomes was assessed using competing-risk models with BVF as a time-dependent covariate. RESULTS: Among 7501 patients, BVF occurred in 380 (5.1%) patients over a median follow-up of 4 (interquartile range, 2-5) years. The cumulative incidence of BVF increased over time, reaching 1.4% at 1 year, 4.6% at 5 years, and 8.3% at 10 years. Independent predictors of BVF included younger age, smoking, balloon-expandable valve, prosthesis size <26 mm, valve-in-valve procedure, mean gradient at discharge >= 15 mm Hg, moderate or severe aortic regurgitation at discharge, and early hemodynamic valve deterioration. BVF was independently associated with an increased risk of all-cause mortality (adjusted hazard ratio, 1.72 [95% CI, 1.47-2.01]; P<0.001), cardiovascular mortality (adjusted hazard ratio, 3.23 [95% CI, 2.73-3.82]; P<0.001), stroke (adjusted hazard ratio, 2.08 [95% CI, 1.08-4.23]; P=0.043), and heart failure hospitalization (adjusted hazard ratio, 1.43 [95% CI, 1.03-1.98]; P=0.032). Consistent findings were observed in different sensitivity analyses. CONCLUSIONS: BVF is a clinically relevant event associated with adverse long-term outcomes. These findings support the implementation of tailored surveillance and preventive strategies to mitigate BVF-related risk.

Datos de la publicación

ISSN/ISSNe:
1941-7640, 1941-7632

Circulation-Cardiovascular Interventions  LIPPINCOTT WILLIAMS & WILKINS

Tipo:
Article
Páginas:
-
PubMed:
42635326

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • aortic valve; aortic valve stenosis; bioprosthesis; heart valve prosthesis; prosthesis failure; transcatheter aortic valve replacement