Contractility sensor-guided optimization of cardiac resynchronization therapy: results from the RESPOND-CRT trial
Fecha de publicación:
Autores con afiliación ISPA
Otros autores
- Brugada, J
- Delnoy, PP
- Brachmann, J
- Reynolds, D
- Padeletti, L
- Noelker, G
- Kantipudi, C
- Dichtl, W
- Borri-Brunetto, A
- Verhees, L
- Ritter, P
- Singh, JP
- RESPOND CRT Investigators
Abstract
Aims Although cardiac resynchronization therapy (CRT) is effective in patients with systolic heart failure (HF) and a wide QRS interval, a substantial proportion of patients remain non-responsive. The SonR contractility sensor embedded in the right atrial lead enables individualized automatic optimization of the atrioventricular (AV) and interventricular (VV) timings. The RESPOND-CRT study investigated the safety and efficacy of the contractility sensor system in HF patients undergoing CRT. Methods and results RESPOND-CRT was a prospective, randomized, double-blinded, multicentre, non-inferiority trial. Patients were randomized (2: 1, respectively) to receive weekly, automatic CRT optimization with SonR vs. an Echo-guided optimization of AV and VV timings. The primary efficacy endpoint was the rate of clinical responders (patients alive, without adjudicated HF-related events, with improvement in New York Heart Association class or quality of life), at 12 months. The study randomized 998 patients. Responder rates were 75.0% in the SonR arm and 70.4% in the Echo arm (mean difference, 4.6%; 95% CI, -1.4% to 10.6%; P<0.001 for non-inferiority margin -10.0%) (Table 2). At an overall mean follow-up of 5486190 days SonR was associated with a 35% risk reduction in HF hospitalization (hazard ratio, 0.65; 95% CI, 0.46-0.92; log-rank P = 0.01). Conclusion Automatic AV and VV optimization using the contractility sensor was safe and as effective as Echo-guided AV and VV optimization in increasing response to CRT.
Datos de la publicación
- ISSN/ISSNe:
- 0195-668X, 1522-9645
- Tipo:
- Article
- Páginas:
- 730-738
- PubMed:
- 27941020
EUROPEAN HEART JOURNAL OXFORD UNIV PRESS
Citas Recibidas en Web of Science: 75
Documentos
- No hay documentos
Filiaciones
Keywords
- SonR; AV and VV optimization; CRT optimization; Cardiac contractility; RESPOND; HF hospitalization; Adaptive CRT
Cita
Brugada, J; Delnoy, PP; Brachmann, J; Reynolds, D; Padeletti, L; Noelker, G; Kantipudi, C; Lopez, JMR; Dichtl, W; Borri Brunetto, A; Verhees, L; Ritter, P; Singh, JP; RESPOND Investigators, CRT. Contractility sensor-guided optimization of cardiac resynchronization therapy: results from the RESPOND-CRT trial. Eur Heart J. 2017. 38. (10). p. 730-738. DOI: 10.1093/eurheartj/ehw526.
Portal de Investigación