Overcoming matrix effects in electrospray: Quantitation of beta-agonists in complex matrices by isotope dilution liquid chromatography-mass spectrometry using singly C-13-labeled analogues
Autores con afiliación ISPA
Otros autores
- Gonzalez-Antuna, A
- Dominguez-Romero, JC
- Garcia-Reyes, JF
- Centineo, G
- Molina-Diaz, A
Abstract
In this work, the implementation of isotope dilution mass spectrometry (IDMS) using minimal labeling and isotope pattern deconvolution (IPD) is evaluated as a strategy for the minimization of matrix effects during trace determination of beta(2)-agonists in complex matrices by liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS). First, the parameters affecting the measurement of isotopic composition of organic compounds by liquid chromatography electrospray ionization high resolution mass spectrometry with a time-of-flight analyzer were evaluated using as a case of study three different beta(2)-agonists: clenbuterol, clenproperol and brombuterol. Then, a calibration graph-free IDMS methodology was evaluated in order to overcome matrix effects in LC-ESI-MS in complex samples. In this procedure singly C-13-labeled analogues of clenbuterol, clenproperol and brombuterol were employed in combination with IPD. Using this approach accurate and precise results were obtained in the simultaneous quantification of beta(2)-agonists in human urine and bovine liver, even at the sub ng g(-1) and particularly in spite of the previously reported matrix effects. Recovery rates in the range of 97-114% in fortified human urine and from 95% to 111% in fortified bovine liver were obtained with RSD (%) of independent recovery experiments always lower than 6%. These results demonstrate that the proposed methodology based on the use of C-13(1)-labeled standards and IPD is a reliable approach for accurate LC-MS quantitation of small molecules and compatible with full-scan high-resolution mass spectrometry. (C) 2013 Elsevier B.V. All rights reserved.
Datos de la publicación
- ISSN/ISSNe:
- 0021-9673, 1873-3778
- Tipo:
- Article
- Páginas:
- 40-47
- PubMed:
- 23523066
JOURNAL OF CHROMATOGRAPHY A ELSEVIER
Citas Recibidas en Web of Science: 46
Documentos
- No hay documentos
Filiaciones
Keywords
- Isotope dilution; Minimal labeling; Quantitation; Matrix effects; Liquid chromatography; Mass spectrometry; beta-Agonists
Cita
Gonzalez Antuna, A; Dominguez Romero, JC; Garcia Reyes, JF; Rodriguez Gonzalez, P; Centineo, G; Alonso, J; Molina Diaz, A. Overcoming matrix effects in electrospray: Quantitation of beta-agonists in complex matrices by isotope dilution liquid chromatography-mass spectrometry using singly C-13-labeled analogues. J. Chromatogr. A. 2013. 1288. p. 40-47. DOI: 10.1016/j.chroma.2013.02.074.